Appendix A. Technical Specifications

This appendix lists the following technical specifications for the SGI Origin 300 server:

Physical and Environmental Requirements

Table A-1 lists the physical and environmental specifications for the SGI Origin 300 server.

Table A-1. Physical and Environmental Specifications

Height

3.46 inches (8.80 cm)

Width

19.0 inches (48.3 cm) (front panel width)
17.07 inches (43.36 cm) (chassis width)

Depth

26 inches (66 cm) (without bezel)
26.8 inches (68.0 cm) (with bezel)

Weight

36.0 lbs (16.4 kg)

Temperature
operating

+5 ˚C (+41 ˚F) to +35 ˚C (+95 ˚F) (up to 1500 m / 5000 ft)
+5 ˚C (+41 ˚F) to +30 ˚C (+86 ˚F) (1500 m to 3000 m / 5,000 ft to 10,000 ft)

Temperature
nonoperating

-40 ˚C (-40 ˚F) to +60 ˚C (+140 ˚F)

Humidity

10% to 95% RH, noncondensing

Altitude

Sea level to 40,000 ft (nonoperating)
Sea level to 10,000 ft (3000 m) (operating)

Noise

50 dB(A) maximum

Heat dissipation

938 Btu/hr maximum


Power Requirements

Table A-2 lists the power requirements of the SGI Origin 300 server.

Table A-2. Power and Cooling Requirements

Power supply voltage

110/220 Vac auto-sensing worldwide

Power supply type

Modified WTX 460 W

Power requirement (maximum)

275 W

Frequency

50/60 Hz

Electrical service

100/120 Vac @15A, 200/240 Vac @16A (single-phase cord)

Service type

North America / Japan (110V), NEMA 5-15R
International (220V), 16 Amp country specific