Chapter 3. Getting Started

This chapter describes all the basic procedures needed to operate your Origin2000 deskside server. For more detailed information about specific components refer to the table of contents or index.

The design of the Origin2000 deskside provides customer maintenance access only to specific components within the system.

The following listed components must be serviced or replaced only by Silicon Graphics trained and approved system support personnel:

Other components and options within the system can be installed or replaced by the end user.


Note: This product requires the use of external shielded cables in order to maintain compliance with Part 15 of the FCC rules.


System Operation Guidelines

The operating procedures described in the following subsections are designed to ensure your safety and the integrity of your new system.

Operating Voltages

The Origin2000 deskside chassis can be configured for either 110-120 VAC or 220-240 VAC operation. The system requires alternating current (AC) service at specified voltage and current ratings for proper operation. The power supply is “auto ranging” and automatically adjusts for operation with either voltage range.


Caution: The deskside system requires the use of a 220-240 Volt electrical source whenever it is configured with more than four R10000 microprocessors (or two Node boards). Other factors may also apply; contact your service provider before upgrading your 110 Volt deskside system.

Verify that the correct AC line voltages are selected for any external peripheral you use with your system.

Before connecting or disconnecting any terminal, peripheral, or front-loading drive, be sure the module System Controller's (MSC) keyswitch is turned to standby and the system circuit breaker located on the back of the chassis is in the off position.

Read the following safety statements carefully before you install or remove any standard or optional components.

Safety Precautions


Warning: Read the following safety information carefully before you install or remove standard or optional components. To avoid electric shock and/or a fire hazard, do not disassemble the deskside chassis. No user-serviceable parts are located inside.

This equipment is sensitive to damage from electrostatic discharge (ESD) caused by the buildup of electrical potential on clothing and other materials.

Before connecting or disconnecting any terminal, peripheral, or front-loading drive, be sure the system is powered off and the primary power source is disconnected.

Attach a ground strap to your wrist when working on the system.

Sliding Open the Front Door Panel

To access the drives and MSC you must open the front door of the deskside system.

Use the following information to open or close the deskside system's front sliding door panel:

  1. Push down on the rectangular panel near the top on the front of the system.

  2. Slide it downward until it locks in position. You should have clear access to the drives and the MSC interface panel (see Figure 3-1).

  3. Close the panel by pushing down until you feel it release.

  4. Let it slide back up into its original closed position.

    Figure 3-1. Opening and Closing the Sliding Front Panel

    Figure 3-1 Opening and Closing the Sliding Front Panel

Removing the System's Plastic Covers

Under certain circumstances you may wish to remove some or all of the plastic covers from the deskside chassis. See “Sliding Open the Front Door Panel” if you need to access only the drives or the MSC front panel.


Note: Do not operate the deskside system with the plastic covers removed. Disruption to normal air flow patterns may cause system overheating.

Use the following steps to remove the plastic covers from the deskside system:

  1. Be sure that the system power is turned off and the power cable is disconnected from the back of the system.

  2. Remove the plastic front panel cover by undoing the captive Phillips-head retaining screw located near the center of the bottom grill (see Figure 3-2).

  3. Lower the panel approximately 0.15 inches (4 mm) and pull it forward off the chassis.

  4. To remove the top cover you must first remove the four corner-positioned cover “caps” by using a screwdriver to release the latch for each one (see Figure 3-3).

  5. Push the screwdriver through the upper grill and unlatch a cap, then lift the cap off. If you have trouble lifting the cap, press down on the outside corner of the cap until it pops up.

  6. Remove the top plastic panel by undoing the captive screw under each cap and lifting the cover straight up off the chassis.


    Note: It is highly unlikely that you will need to remove the rear plastic “bumper” cover or side panels. These three plastic covers are interconnected and somewhat difficult to remove. If you find it necessary, contact your service provider for assistance.

    Figure 3-2. Removing the Front Plastic Panel

    Figure 3-2 Removing the Front Plastic Panel

    Figure 3-3. Removing the Top Plastic Panel

    Figure 3-3 Removing the Top Plastic Panel

System Drives

The Origin2000 deskside system comes standard with six drive bays. The first is located in the upper left sector on the front of the system and holds one 5.25-inch half-height CD-ROM drive. This single-ended drive bay is “hard wired” as SCSI ID 6 on the backplane. To the right of this bay is the MSC and then a bank of five 3.5-inch disk bays (see Figure 3-4).

The system disk is always SCSI ID 1 and is always installed in the disk drive bay directly to the right of the MSC. Each of the five disk drive bays is “hard wired” on the backplane to a single SCSI ID number (1-5). This prevents ever assigning the same SCSI ID to more than one drive installed in the deskside chassis.


Caution: When you remove a drive be sure that you always put it back in the same bay that you removed it from. Placing the system disk in the wrong bay results in the system being unable to boot. Replacing a data disk in a different bay may cause file corruption, data loss, or other malfunction.

See the information in Chapter 5 for details on removing, replacing, or installing drives in the deskside chassis.


Caution: Use proper handling and storage procedures to avoid the loss of data and equipment. Do not remove disk drives while they are operating. Always power off the system before removing a drive.

Be sure to use standard electrostatic discharge prevention precautions when removing, storing, transporting, or replacing drives.

All hard disk drives installed in the system must be Ultra SCSI or SCSI-2 compatible and use 80-pin single-connector assembly (SCA) drive sleds.

Use of external SCSI devices is supported through the BaseIO and optional XIO boards that install in the back of the system. See Chapter 5, “Installing and Replacing Customer Replaceable Units,” for additional information.

Figure 3-4. Deskside System Internal Drive Bays

Figure 3-4 Deskside System Internal Drive Bays

Connecting to an Ethernet

Your Origin2000 deskside system comes standard with an 8-pin 100-Mb-per-second Ethernet connector.


Note: Always verify the type of signal being transmitted over your network cable before plugging in the connector. Some networks use a twisted-pair cabling system that carries AUI signals. These networks use an RJ-45 connector that is meant to be plugged into an IEEE 802.3 Transceiver unit.

You can order optional Silicon Graphics XIO boards for additional Ethernet connections.

Observe the following procedures when making Ethernet connections:

  1. Identify the Ethernet drop intended for your deskside system, and route it to the rear of the chassis. Repeat for any additional connections.

  2. Plug in the Ethernet connector (make sure to properly secure the 8-pin connector).

  3. Continue with any additional peripheral connections or installations.

  4. Restart the system.

Powering On the Origin2000 Deskside System

Use the following procedures to power on your new Origin2000 deskside system:

  1. Make sure the power switches on all of the equipment are turned off.

  2. Plug the power cord into each component. Make sure to connect the cords to grounded outlets only.

  3. Turn on the power switches in the following order:

    • breaker switch located on the power-in panel on the back of the chassis

    • monitors, terminals or other video output devices

    • printer (if installed)

    • MSC key switch

  4. After you turn the MSC's switch to the On position, watch the LED panel for the [SYS OK] message. See Figure 3-5 for the keyswitch and other front panel switch locations.


Note: Pushing either of the reset buttons during the boot process causes the system to abort the normal boot process.

To better understand the MSC and its front panel interface, see Chapter 6, “Using the Module System Controller,” for more detailed information.

Figure 3-5. MSC Keyswitch and Front-Panel Controls

Figure 3-5 MSC Keyswitch and Front-Panel Controls

Powering Off the Origin2000 Deskside System

The Origin2000 deskside system should be completely powered off only for relocation, routine maintenance, or repair. Warn everyone who uses the system before you shut it down. Before beginning this procedure, log out and shut down the software using the instructions that follow:

  1. To halt operating system activity and prepare the system for power off, become superuser and enter /etc/halt in a functional IRIX window. The /etc/halt command gracefully shuts down the system software and leaves you at the PROM monitor level. If you are remotely logged in to the system, you will be prompted before the shutdown procedure is executed.

  2. Turn the MSC key switch to the standby position to eliminate power to the boards and peripherals.

  3. Switch the system circuit breaker to the off position to eliminate all power to the midplane and power supply (see Figure 3-6 for the location of the switch).

  4. Unplug the power cord from the socket if you need to cut off all electrical power to the system.

    Figure 3-6. System Power Cable and Switch

    Figure 3-6 System Power Cable and Switch